3.0 Test Program

3.1 Temperature / Humidity Tests

3.1.1 Test Procedure

The Temperature / Humidity Tests were conducted in accordance with NEMA TS2-1998, Paragraphs 2.2.7.3 thru 2.2.7.7 and the Test Profile of Table 2-1, with the following details.

The Test Unit was placed within a temperature-humidity chamber in a manner simulating actual usage conditions with all electrical wires required for Operational Tests exteded through a chamber port. Photographs of the test setup may be seen in Appendix A of this report.

The chamber temperature and humidity conditions were recorded throughout the following tests. The Test Unit was operated continuously at the input voltage and test conditions described below. Verification of proper operation was by visual examination. The Test Unit was initially operated at 120 Volts AC, 60 Hz. at room ambient conditions to verify proper operation.

-30°F to +40°F
+40°  F
+50°  F
+60°  F
+70°  F
+80°  F
+90°  F
+100°F
+110°F
+120°F
+130°F
+140°F
+150°F
+160°F
+165°F
Humidity Turned Off
75 % R.H.
80 % R.H.
83 % R.H.
86 % R.H.
87 % R.H.
89 % R.H.
89 % R.H.
90 % R.H.
70 % R.H.
50 % R.H.
38 % R.H.
28 % R.H.
21 % R.H.
18 % R.H.